TY - JOUR
T1 - Fast and reliable determination of the antifungal drug voriconazole in plasma using monolithic silica rod liquid chromatography
AU - Wenk, Markus
AU - Droll, Armin
AU - Krähenbühl, Stephan
PY - 2006/3/7
Y1 - 2006/3/7
N2 - In the present study, we developed a fast and reliable HPLC assay for the determination of the new triazole antifungal agent voriconazole in plasma, using a Chromolith® RP 18e (100 mm × 4.6 mm) monolithic silica rod HPLC column. After liquid-liquid extraction, plasma samples were separated with a mobile phase consisting of ammoniumdihydrogencarbonate buffer (pH 5.8)-acetonitrile-tetrahydrofuran (72:25:3) at a flow-rate of 3.5 mL/min and UV detection at 255 nm. The retention times for voriconazole and internal standard (UK-115794) were 2.3 and 2.7 min, respectively, and total run time was 4 min. The calibration curves were linear between 0.05 and 10 μg/mL, and within-assay and between-assay coefficients of variation were <4%. The proposed assay for voriconazole in plasma is fast, sensitive and reliable, and, thus, well suited for routine therapeutic monitoring of patients and for pharmacokinetic studies. It can be predicted that the use of monolithic silica rod chromatography will substantially shorten the turn-around time in the therapeutic drug monitoring laboratory.
AB - In the present study, we developed a fast and reliable HPLC assay for the determination of the new triazole antifungal agent voriconazole in plasma, using a Chromolith® RP 18e (100 mm × 4.6 mm) monolithic silica rod HPLC column. After liquid-liquid extraction, plasma samples were separated with a mobile phase consisting of ammoniumdihydrogencarbonate buffer (pH 5.8)-acetonitrile-tetrahydrofuran (72:25:3) at a flow-rate of 3.5 mL/min and UV detection at 255 nm. The retention times for voriconazole and internal standard (UK-115794) were 2.3 and 2.7 min, respectively, and total run time was 4 min. The calibration curves were linear between 0.05 and 10 μg/mL, and within-assay and between-assay coefficients of variation were <4%. The proposed assay for voriconazole in plasma is fast, sensitive and reliable, and, thus, well suited for routine therapeutic monitoring of patients and for pharmacokinetic studies. It can be predicted that the use of monolithic silica rod chromatography will substantially shorten the turn-around time in the therapeutic drug monitoring laboratory.
KW - HPLC
KW - Monolithic columns
KW - Therapeutic drug monitoring
KW - Voriconazole
UR - http://www.scopus.com/inward/record.url?scp=33644761838&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2006.01.015
DO - 10.1016/j.jchromb.2006.01.015
M3 - Article
C2 - 16488671
AN - SCOPUS:33644761838
SN - 1570-0232
VL - 832
SP - 313
EP - 316
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 2
ER -