TY - GEN
T1 - Hysteresis Current Control of Single-Phase Single-Stage Grid-Connected Inverter with Buck-Boost Operation Capability
AU - Komurcugil, Hasan
AU - Guler, Naki
AU - Bayhan, Sertac
AU - Guzman, Ramon
N1 - Publisher Copyright:
© 2023 IEEE.
PY - 2023
Y1 - 2023
N2 - This paper presents a hysteresis current control for single-phase single-stage buck-boost grid-connected inverters. The inverter topology employs four switches that are operated with the grid frequency and two bidirectional switches that are operated with high switching frequency. Hence, unlike the existing single-stage inverter topologies, the switching losses are minimized. Moreover, this inverter configuration has the capability to operate both in buck and boost modes and utilizes only a single inductor. The proposed hysteresis current control eliminates the need for designing a dedicated modulation technique for this inverter topology. An active damping technique is utilized to cope with the resonance damping problem without employing additional sensor. The reference current needed in the hysteresis controller is produced using a proportional-resonant (PR) controller whose input is the grid current error. The use of PR controller guarantees zero steady-state error in the grid current. The validity and superiority of the proposed control method are confirmed by MATLAB/Simulink simulations under various operating conditions which include buck mode, boost mode, transition from boost mode to buck mode, reference current change and virtual resistor variation. The simulation results show that the proposed control method is able to transfer the desired current into grid successfully under all operating conditions.
AB - This paper presents a hysteresis current control for single-phase single-stage buck-boost grid-connected inverters. The inverter topology employs four switches that are operated with the grid frequency and two bidirectional switches that are operated with high switching frequency. Hence, unlike the existing single-stage inverter topologies, the switching losses are minimized. Moreover, this inverter configuration has the capability to operate both in buck and boost modes and utilizes only a single inductor. The proposed hysteresis current control eliminates the need for designing a dedicated modulation technique for this inverter topology. An active damping technique is utilized to cope with the resonance damping problem without employing additional sensor. The reference current needed in the hysteresis controller is produced using a proportional-resonant (PR) controller whose input is the grid current error. The use of PR controller guarantees zero steady-state error in the grid current. The validity and superiority of the proposed control method are confirmed by MATLAB/Simulink simulations under various operating conditions which include buck mode, boost mode, transition from boost mode to buck mode, reference current change and virtual resistor variation. The simulation results show that the proposed control method is able to transfer the desired current into grid successfully under all operating conditions.
KW - Single-stage
KW - buck-boost
KW - grid-connected inverter
KW - hysteresis current control
KW - proportional-resonant control
UR - http://www.scopus.com/inward/record.url?scp=85179502650&partnerID=8YFLogxK
U2 - 10.1109/IECON51785.2023.10312391
DO - 10.1109/IECON51785.2023.10312391
M3 - Conference contribution
AN - SCOPUS:85179502650
T3 - IECON Proceedings (Industrial Electronics Conference)
BT - IECON 2023 - 49th Annual Conference of the IEEE Industrial Electronics Society
PB - IEEE Computer Society
T2 - 49th Annual Conference of the IEEE Industrial Electronics Society, IECON 2023
Y2 - 16 October 2023 through 19 October 2023
ER -