TY - GEN
T1 - Post fault operation of a dual matrix converter fed open-end load
AU - Iqbal, Atif
AU - Rahman, Khaliqur
AU - Al-ammari, Rashid
AU - Abu-Rub, Haitham
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/6/16
Y1 - 2015/6/16
N2 - This paper investigates the fault tolerant control strategies for a three to five-phase dual matrix converter fed open-end load system. There are two three to five phase matrix converter at both the ends of the load. In healthy condition both the matrix converters are sharing the load according to their modulation index. After the occurrence of an open-circuit fault in one of the matrix converter, it is disconnected and the other remaining converter shares the load according to its capacity (maximum rating is half of the dual converter). In the proposed scheme both the converters are sharing the load equally under normal operating conditions. After the clearance of fault, again both the matrix converters start working normally and sharing the load equally. In this paper it is shown that in a dual matrix converter supply system, they can work in healthy condition, post-fault condition and after clearance of the fault without break in continuity of the supply. Space vector pulse width modulation technique is used for control of the dual matrix converters under normal and post-fault conditions. Here open-end five-phase R-L load is taken for validation of the technique. Simulated results are verified experimentally.
AB - This paper investigates the fault tolerant control strategies for a three to five-phase dual matrix converter fed open-end load system. There are two three to five phase matrix converter at both the ends of the load. In healthy condition both the matrix converters are sharing the load according to their modulation index. After the occurrence of an open-circuit fault in one of the matrix converter, it is disconnected and the other remaining converter shares the load according to its capacity (maximum rating is half of the dual converter). In the proposed scheme both the converters are sharing the load equally under normal operating conditions. After the clearance of fault, again both the matrix converters start working normally and sharing the load equally. In this paper it is shown that in a dual matrix converter supply system, they can work in healthy condition, post-fault condition and after clearance of the fault without break in continuity of the supply. Space vector pulse width modulation technique is used for control of the dual matrix converters under normal and post-fault conditions. Here open-end five-phase R-L load is taken for validation of the technique. Simulated results are verified experimentally.
KW - Dual Matrix Converter
KW - Five-phase
KW - Multiphase open-end load
KW - Post fault operation
KW - Space vector pulse width modulation (SVPWM)
UR - http://www.scopus.com/inward/record.url?scp=84937719662&partnerID=8YFLogxK
U2 - 10.1109/ICIT.2015.7125247
DO - 10.1109/ICIT.2015.7125247
M3 - Conference contribution
AN - SCOPUS:84937719662
T3 - Proceedings of the IEEE International Conference on Industrial Technology
SP - 1117
EP - 1122
BT - 2015 IEEE International Conference on Industrial Technology, ICIT 2015
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2015 IEEE International Conference on Industrial Technology, ICIT 2015
Y2 - 17 March 2015 through 19 March 2015
ER -